About Steri ETO Table Top Autoclave
Type: ETO SterilizerChamber Volume: 41-80 Ltrs (as per Ser requirement)
Sterilizing Temperature: Minimum as per user setting-Maximum-70 Deg C
Design standards as per European CE standard
Chamber Size: As per Requirement
Door: Single Hinged Door
Material of construction: Chamber made of SS 304, Non contact , parts-SS 304, Insulation 75/100 mm thick mineral wool, piping-SS 304, Door-SS 304, Door sealant-High grade silicon gasket
Internal Mirror and external matt finishing. The equipment is smooth finished without any sharp edges and crevices.
Manual operation control by switches.
Sterilization pressure range-0.1 to 1bar
Sterilization temperature range- Min: Room Temperature-Max:60 Deg C.
Sterile Hold Time-Min: 300 min, Max: As required
Vacuum (Range)- Range: -0.4 to -0.7
The machine is equipped with positive pressure mechanical door locking system which must not allow user to open the door until the atmospheric pressure is achieved inside the chamber.
The machine is equipped with inbuilt steam generator.
The machine is able to maintain humidity in the chamber within the range of 90 to 95% automatically controlled by wet and dry humidity transducer system.
Pressure of the sterilant is controlled automatically through pressure sensor.
The machine is able to manual control the aeration phase of the cycle to remove residual gas from the chamber.
The Sterilizer has Hinged Single Door with Shooting bolts locking system.
Door frame is strong & robust enough to ensure smooth door movement & consistency in alignment.
Door movement is smooth to ensure proper door alignment over a long period of time.
Door has Single safety lock, at least one mechanical locking mechanism.
The Machine will beequipped with Mechanical Door lock detection system which must not allow user to
open the door until the atmospheric pressure is achieved inside the chamber.
Catalytic convertor is provided to treat the ETO gas before draining.
Vacuum Pump is provided.
Other Safety features:
The sterilizer will be hydraulically tested at 2.5 times the working pressure.
The sterilizer has safety valve for added safetyHigh-Quality Stainless Steel BuildManufactured with Stainless Steel 304/316, the Steri ETO Table Top Autoclave ensures exceptional durability and resistance to corrosion. The internal and external stainless steel construction supports ease of cleaning and maintains a sterile environment, ideal for clinical and laboratory use.
User-Friendly and Safe OperationEquipped with a fully automatic PLC-based control panel, this autoclave is simple to operate and includes multiple safety interlocks for enhanced user protection. The audio-visual alarm system and graphical LCD display provide real-time monitoring and alerts, ensuring every sterilization cycle runs seamlessly.
Flexible and Reliable SterilizationFeaturing pre-programmed as well as customizable cycle settings, the autoclave adapts to different sterilization needs. The temperature can be adjusted from room temperature up to 60C, and the high-density glass wool insulation ensures temperature uniformity for optimal results every cycle.
FAQ's of Steri ETO Table Top Autoclave:
Q: How does the pre-programmed and user-selectable cycle feature work in the Steri ETO Table Top Autoclave?
A: The autoclave allows users to choose from pre-set sterilization cycles for standard procedures or customize cycles based on specific requirements. Adjustments can be made to temperature (from 37C to 55C) and sterilization time (between 0 and 99 minutes), ensuring adaptability for various applications.
Q: What are the primary benefits of the fully automatic PLC-based control panel?
A: The fully automatic PLC-based control panel streamlines operation, automates cycle management, and reduces the risk of human error. It offers graphical feedback via LCD display, enabling precise control and real-time monitoring throughout the sterilization process.
Q: Where can this table top ETO autoclave be effectively used?
A: This autoclave is ideal for hospitals, laboratories, research institutions, and pharmaceutical companies in India. Its compact tabletop design makes it suitable for environments where space is limited but reliable sterilization is critical.
Q: When should the documentation (IQ, OQ, PQ & DQ) provided with the autoclave be used?
A: The IQ, OQ, PQ, and DQ documents are essential for commissioning and validating the autoclave. Use them during installation to confirm correct setup (IQ), during regular operation checks (OQ), for process validation (PQ), and to verify design compliance (DQ) to meet regulatory standards.
Q: What safety features are integrated into the Steri ETO Table Top Autoclave?
A: Safety is ensured through door and process interlocks, audio-visual alarms, pressure release valves, and temperature control. These systems work together to protect both the user and the equipment during operation.
Q: How is the ETO (Ethylene Oxide) cartridge managed in this autoclave?
A: A dedicated ETO cartridge holder is provided, allowing for safe insertion and containment during sterilization. The system's design ensures even ETO distribution within the chamber, maximizing sterilization efficiency while minimizing risks.
Q: What advantage does the inbuilt steam generator provide?
A: The inbuilt steam generator allows for consistent and thorough humidity control during the sterilization process, enhancing the effectiveness of ETO sterilization and reducing the need for external steam sources or additional equipment.